301 resultados para multifocal electroretiogram


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine whether there is a difference in neuroretinal function and in macular pigment optical density between persons with high- and low-risk gene variants for age-related macular degeneration (AMD) and no ophthalmoscopic signs of AMD, and to compare the results on neuroretinal function to patients with manifest early AMD. Methods and Participants: Neuroretinal function was assessed with the multifocal electroretinogram (mfERG) for 32 participants (22 healthy persons with no AMD and 10 early AMD patients). The 22 healthy participants with no AMD had high- or low-risk genotypes for either CFH (rs380390) and/or ARMS2 (rs10490924). Trough-to-peak response densities and peak-implicit times were analyzed in 5 concentric rings. Macular pigment optical densitometry was assessed by customized heterochromatic flicker photometry. Results: Trough-to-peak response densities for concentric rings 1 to 3 were, on average, significantly greater in participants with high-risk genotypes than in participants with low-risk genotypes and in persons with early AMD after correction for age and smoking (p<0.05). The group peak- implicit times for ring 1 were, on average, delayed in the patients with early AMD compared with the participants with high- or low-risk genotypes, although these differences were not significant. There was no significant correlation between genotypes and macular pigment optical density. Conclusion: Increased neuroretinal activity in persons who carry high-risk AMD genotypes may be due to genetically determined subclinical inflammatory and/or histological changes in the retina. Neuroretinal function in healthy persons genetically susceptible to AMD may be a useful additional early biomarker (in combination with genetics) before there is clinical manifestation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate early functional changes of local retinal defects in type II diabetic patients using the global flash multifocal electroretinogram (MOFO mfERG). Methods: Thirty-eight diabetic patients and 14 age-matched controls were recruited. Nine of the diabetics were free from diabetic retinopathy (DR), while the remainder had mild to moderate non-proliferative diabetic retinopathy. The MOFO mfERG was performed at high (98%) and low (46%) contrast levels. MfERG responses were grouped into 35 regions for comparison with DR classification at those locations. Z-scores of the regional mfERG responses were compared across different types of DR defects. Results: The mfERG waveform consisted of the direct component (DC) and the induced component (IC). Local reduction in DC and IC amplitudes were found in diabetic patients with and without DR. With increasing severity of retinopathy, there was a further deterioration in amplitude of both components. Under MOFO mfERG paradigm, amplitude was a useful screening parameter. Conclusion: The MOFO mfERG can help in detecting early functional anomalies before the appearance of visible signs, and may assist in monitoring further functional deterioration in diabetic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the correlations of the global flash multifocal electroretinogram (MOFO mfERG) with common clinical visual assessments – Humphrey perimetry and Stratus circumpapillary retinal nerve fiber layer (RNFL) thickness measurement in type II diabetic patients. Methods: Forty-two diabetic patients participated in the study: ten were free from diabetic retinopathy (DR) while the remainder suffered from mild to moderate non-proliferative diabetic retinopathy (NPDR). Fourteen age-matched controls were recruited for comparison. MOFO mfERG measurements were made under high and low contrast conditions. Humphrey central 30-2 perimetry and Stratus OCT circumpapillary RNFL thickness measurements were also performed. Correlations between local values of implicit time and amplitude of the mfERG components (direct component (DC) and induced component (IC)), and perimetric sensitivity and RNFL thickness were evaluated by mapping the localized responses for the three subject groups. Results: MOFO mfERG was superior to perimetry and RNFL assessments in showing differences between the diabetic groups (with and without DR) and the controls. All the MOFO mfERG amplitudes (except IC amplitude at high contrast) correlated better with perimetry findings (Pearson’s r ranged from 0.23 to 0.36, p<0.01) than did the mfERG implicit time at both high and low contrasts across all subject groups. No consistent correlation was found between the mfERG and RNFL assessments for any group or contrast conditions. The responses of the local MOFO mfERG correlated with local perimetric sensitivity but not with RNFL thickness. Conclusion: Early functional changes in the diabetic retina seem to occur before morphological changes in the RNFL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: UC is a disease of the entire urothelium, characterized by multiplicity and multifocality. The clonal relationship among multiple UCs has implications regarding adjuvant chemotherapy. It has been investigated in studies of chromosomal alteration and single gene mutation. However, these genetic changes can occur in unrelated tumors under similar carcinogenic selection pressures. Tumors with high MSI have numerous DNA mutations, of which many provide no selection benefit. While these tumors represent an ideal model for studying UC clonality, their low frequency has prevented their previous investigation. Materials and Methods: We investigated 32 upper and lower urinary tract UCs with high MSI and 4 nonUC primary cancers in 9 patients. We used the high frequency and specificity of individual DNA mutations in these tumors (MSI at 17 loci) and the early timing of epigenetic events (methylation of 7 gene promoters) to investigate tumor clonality. Results: Molecular alterations varied among tumors from different primary organs but they appeared related in the UCs of all 9 patients. While 7 patients had a high degree of concordance among UCs, in 2 the UCs shared only a few similar alterations. Genetic and epigenetic abnormalities were frequently found in normal urothelial samples. Conclusions: Multiple UCs in each patient appeared to arise from a single clone. The molecular order of tumor development varied from the timing of clinical presentation and suggested that residual malignant cells persist in the urinary tract despite apparent curative surgery. These cells lead to subsequent tumor relapse and new methods are required to detect and eradicate them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose to evaluate the effects of the wearer’s pupil size and spherical aberration on visual performance with centre-near, aspheric multifocal contact lenses (MFCLs). The advantage of binocular over monocular vision was also investigated. Methods Twelve young volunteers, with an average age of 27±5 years, participated in the study. LogMAR Visual Acuity (VA) was measured under cycloplegia for a range of defocus levels (from +3.0 to -3.0D, in 0.5D steps) with no correction and with three aspheric MFCLs (Air Optix Aqua Multifocal, Ciba Vision, Duluth, GA, US) with a centre-near design, providing correction for “Low”, “Med” and “High” near demands. Measurements were performed for all combinations of the following conditions: i) artificial pupils of 6mm and 3mm diameter, ii) binocular and monocular (dominant eye) vision. Depth-of-focus (DOF) was calculated from the VA vs. defocus curves. Ocular aberrations under cycloplegia were measured using iTrace. Results VA at -3.0D defocus (simulating near performance) was statistically higher for the 3mm than for the 6mm pupil (p=0.006), and for binocular rather than for monocular vision (p<0.001). Similarly, DOF was better for the 3mm pupil (p=0.002) and for binocular viewing conditions (p<0.001, ANOVA). Both VA at –3.0D defocus and DOF increased as the “addition” of the MFCL correction increased. Finally, with the centre-near MFCLs a linear correlation was found between VA at –3.0D defocus and the wearer’s ocular spherical aberration (R2=0.20 p<0.001 for 6mm data), with the eyes exhibiting the higher positive spherical aberration experiencing lower VAs. By contrast, no correlation was found between VA and spherical aberration at 0.00D defocus (distance vision). Conclusions Both near VA and depth-of-focus improve with these MFCLs, with the effects being more pronounced for small pupils and binocular than for monocular vision. Coupling of the wearer’s ocular spherical aberration with the aberration profiles provided by MFCLs affects their functionality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In animal models hemi-field deprivation results in localised, graded vitreous chamber elongation and presumably deprivation induced localised changes in retinal processing. The aim of this research was to determine if there are variations in ERG responses across the retina in normal chick eyes and to examine the effect of hemi-field and full-field deprivation on ERG responses across the retina and at earlier times than have previously been examined electrophysiologically. Methods: Chicks were either untreated, wore monocular full-diffusers or half-diffusers (depriving nasal retina) (n = 6-8 each group) from day 8. mfERG responses were measured using the VERIS mfERG system across the central 18.2º× 16.7º (H × V) field. The stimulus consisted of 61 unscaled hexagons with each hexagon modulated between black and white according to a pseudorandom binary m-sequence. The mfERG was measured on day 12 in untreated chicks, following 4 days of hemi-field diffuser wear, and 2, 48 and 96 h after application of full-field diffusers. Results: The ERG response of untreated chick eyes did not vary across the measured field; there was no effect of retinal location on the N1-P1 amplitude (p = 0.108) or on P1 implicit time (p > 0.05). This finding is consistent with retinal ganglion cell density of the chick varying by only a factor of two across the entire retina. Half-diffusers produced a ramped retina and a graded effect of negative lens correction (p < 0.0001); changes in retinal processing were localized. The untreated retina showed increasing complexity of the ERG waveform with development; form-deprivation prevented the increasing complexity of the response at the 2, 48 and 96 h measurement times and produced alterations in response timing. Conclusions: Form-deprivation and its concomitant loss of image contrast and high spatial frequency images prevented development of the ERG responses, consistent with a disruption of development of retinal feedback systems. The characterisation of ERG responses in normal and deprived chick eyes across the retina allows the assessment of concurrent visual and retinal manipulations in this model. (Ophthalmic & Physiological Optics © 2013 The College of Optometrists.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Many contact lens (CL) manufacturers produce simultaneous-image lenses in which power varies either smoothly or discontinuously with zonal radius. We present in vitro measurements of some recent CLs and discuss how power profiles might be approximated in terms of nominal distance corrections, near additions, and on-eye visual performance. Methods Fully hydrated soft, simultaneous-image CLs from four manufacturers (Air Optix AQUA, Alcon; PureVision multifocal, Bausch & Lomb; Acuvue OASYS for Presbyopia, Vistakon; Biofinity multifocal- ‘‘D’’ design, Cooper Vision) were measured with a Phase focus Lens Profiler (Phase Focus Ltd., Sheffield,UK) in a wet cell and powerswere corrected to powers in air. All lenses had zero labeled power for distance. Results Sagittal power profiles revealed that the ‘‘low’’ add PureVision and Air Optix lenses exhibit smooth (parabolic) profiles, corresponding to negative spherical aberration. The ‘‘mid’’ and ‘‘high’’ add PureVision and Air Optix lenses have biaspheric designs, leading to different rates of power change for the central and peripheral portions. All OASYS lenses display a series of concentric zones, separated by abrupt discontinuities; individual profiles can be constrained between two parabolically decreasing curves, each giving a valid description of the power changes over alternate annular zones. Biofinity lenses have constant power over the central circular region of radius 1.5 mm, followed by an annular zone where the power increases approximately linearly, the gradient increasing with the add power, and finally an outer zone showing a slow, linear increase in power with a gradient being almost independent of the add power. Conclusions The variation in power across the simultaneous-image lenses produces enhanced depth of focus. The throughfocusnature of the image, which influences the ‘‘best focus’’ (distance correction) and the reading addition, will vary with several factors, including lens centration, the wearer’s pupil diameter, and ocular aberrations, particularly spherical aberration; visual performance with some designs may show greater sensitivity to these factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:Multifocal contact lenses (MCLs) have been available for decades. A review of the literature suggests that while, historically, these lenses have been partially successful, they have struggled to compete with monovision (MV). More recent publications suggest that there has been an improvement in the performance of these lenses. This study set out to investigate whether the apparent improved lens performance reported in the literature is reflected in clinical practice. Methods:Data collected over the last 5yrs via the International Contact Lens Prescribing Survey Consortium was reviewed for patients over the age of 45yrs. The published reports of clinical trials were reviewed to assess lens performance over the time period. Results:Data review was of 16,680 presbyopic lens fits in 38 countries. The results are that 29% were fit with MCLs, 8% MV and 63% single vision (SV). A previous survey conducted in Australia during 1988-89 reported that 9% of presbyopes were fit with MCLs, 29% MV and 63% SV. The results from our survey for Australia alone were 28% (MV 13%) vs 9% (MV 29%) suggesting an increase in usage of MCLs from 1988-89 to 2010. A review of the literature indicates the reported level of visual acuities with MCLs in comparison to MV has remained equivalent over this time period, yet preference has switch from MV to MCLs. Conclusions:There is evidence that currently more MCLs than MV are being fit to presbyopes, compared to 1988-89. This increased use is likely due to the improved visual performance of these lenses, which is not demonstrated with acuity measures but reported by wearers, suggesting that patient-based subjective ratings are currently the best way to measure visual performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To determine neuroretinal function with multifocal electroretinogram (mfERG) in diabetic subjects without retinopathy. Methods Multifocal electroretinogram (mfERG) was performed in 18 eyes of 18 diabetic subjects without retinopathy and 17 eyes of 17 age and gender-matched healthy control participants. Among 18 diabetic subjects, two had type 1 and 16 had type 2 diabetes. MfERG responses were averaged by the retinal areas of six concentric rings and four quadrants, and 103 retinal locations; N1–P1 amplitude and P1-implicit time were analysed. Results Average mfERG N1–P1 amplitude (in nv/deg2) of 103 retinal locations was 56.3 ± 17.2 (mean ± SD) in type 1 diabetic subjects, 47.2 ± 9.3 in type 2 diabetic subjects and 71.5 ± 12.7 in controls. Average P1-implicit time (in ms) was 43.0 ± 1.3 in type 1 diabetic subjects, 43.9 ± 2.3 in type 2 diabetic subjects and 41.9 ± 2.1 in controls. There was significant reduction in average N1–P1 amplitude and delay in P1-implicit time in type 2 diabetic subjects in comparison to controls. mfERG amplitude did not show any significant correlation with diabetes duration and blood sugar level. However, implicit time showed a positive correlation with diabetes duration in type 2 diabetic subjects with diabetes duration ≥5 years. Conclusions This is the first study in a Nepalese population with diabetes using multifocal electroretinography. We present novel findings that mfERG N1–P1 amplitude is markedly reduced along with delay in P1-implicit time in type 2 diabetic subjects without retinopathy. These findings indicate that there might be significant dysfunction of inner retina before the development of diabetic retinopathy in the study population, which have higher prevalence of diabetes than the global estimate and uncontrolled blood sugar level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this letter I propose the name "Proliferative Multifocal Leukoplakia" with the goal of reducing under-diagnosis of this disease, improve the early diagnosis, try to make an early therapy and control, and prevent its malignant transformation.